EonStor 8-Bay Cube SAS-SATA
Uncompressed 10-bit 1080 HD Kurgu EonStar A08S-C2131 8 slotlu SATA II-SAS Raid Subsystem
SAS host interface technology High bandwidth, provide satisfactory processing efficiency even in transaction-intensive and throughput-demanding applications

5th generation, ASIC400 architecture:

* Hardware RAID5 + RAID6 engine

Advanced fault tolerance, ensure data integrity even in multiple drive failure events
Supports video streams up to uncompressed 10-bit 1080 HD Can be used to do video and content editing projects
Powerful management suite, SANWatch, support Easy management and monitoring of your subsystem anywhere through Intranet or Internet
Convertible configuration: tower or desktop Flexibly fit the space allocations; when in desktop configuration, four subsystems can be stacked together
Two colors of enclosure: black or silver Consistent integration with the color tone of the setting environment

Flexible choice:

* 1 PSU and 1 SAS port (A08S-C2131)
* 2 PSUs and 2 SAS ports (A08S-C2132)
* optional installation of 1 additional PSU for A08S-C2131

Make your money spent on what you really need
Drive interface: 3Gbps SATA-II disk drives Affordable choice for high capacity
Fault-tolerant hardware Redundant PSU and cooling modules enable high availability

Low noise:

* noise lower than 41 dBA when the fans in low speed mode

Low acoustic noise for SOHO or small-business environments

Host Interface

* One (1) SAS wide port (SFF-8088) with 12Gbps bandwidth
* Concurrent I/O commands
* Default tagged command queuing: 256

Drive Interface

* Eight (8) 3.0Gbps SATA-II, hot-swappable drive trays
* Accommodates 1-inch pitch, 3.5-inch SATA-II (3Gbps) disk drives
* S.M.A.R.T. and NCQ support
* Automatic bad-sector reassignment
* Dedicated bandwidth to each connected drive
* Drive buffer on/off switch

Controller Single
Form Factor 8-bay Cube tower or desktop convertible
RAID functionality

* Global or Dedicated hot-spare
* RAID levels supported: RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60
* Online expansion by:
o Adding new drives
o Copying and replacing drives with drives of larger capacity
* RAID migration
* Configurable stripe size and write policy per array
* Intelligent drive handling:
o In degraded mode: skips irreparable blocks to continue rebuild
o In normal operation: data-block verification and repair

System Components

* One (1) tower/desktop convertible enclosure (black or silver)
* One(1) RAID controller module
* One (1) 256 MB DIMM module (pre-installed module)
* One (1) 250W power supply unit
* Two (2) redundant, dual-speed cooling modules
* Eight (8), hot-swappable drive trays (black or silver)
* Optional Li-Ion battery backup unit (BBU), life expectancy and charge level aware

Management

* Java-based SANWatch software
* COM1 serial port for local access to firmware-embedded utility
* Automated cache flush and caching mode operation per enclosure status
* GUI, Telnet, and SSH system monitoring via Ethernet
* Firmware-embedded manager via RS-232C (audio jack) that is platform independent
* Various event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN
* LCD keypad panel for monitoring and access to all configuration options
* Module status LED indicators:
* Component presence detection & thermal sensors via I2C bus

Dimensions 370(H) x 155(W) x 343(D) mm
Weight 11.4 kg
Kullanım Alanları
HD Video Kurgu
Grafik işleme
Video işleme
Sayfa tasarımı
CAD-CAM
Avantajları
Masaüstünde yüksek kapasiteli depolama imkanı. 8 TB'ye kadar büyüyebilen kapasite. Yüksek performans ve yüksek güvenlik seviyesi. Masaüstü yayıncılık, sayfa tasarımı, grafik uygulamaları, video uygulamaları için çok uygun.
GENEL TEKNİK ÖZELLİKLER
Arabirimler1 Adet SAS wide port (SFF-8088) 12Gbps bandwidth
ArabirimlerSATA II 3GBps Diskler
Raid SeviyeleriRAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60
Güç Kaynağı / FAN1 Adet Power Supply Ünitesi(250W), Dual Speed Redundant Fan Modül
GüvenlikSNMP Desteği
Disk YönetimiS.M.A.R.T. ve NCQ desteği
Disk YönetimiOtomatik bad-sector denetleyici
Disk YönetimiBağlantılı herbir disk için tanımlanabilir bant genişliği
Disk YönetimiDrive buffer on/off switch
KontrollörTek
Ünite YapısıDik veya yatık şekilde kullanım imkanı
Raid ÖzellikleriOnline olarak yeni disk ekleme, kopyalama ve düzeltme işlemleri
Raid ÖzellikleriRAID migration
Raid ÖzellikleriConfigurable stripe size and write policy per array
Ünite Bellek256 MB DDR Ram
Yönetim ÖzellikleriWeb arayüzü üzerinden JAVA tabanlı SAN-Watch yazılımı
Yönetim ÖzellikleriCOM1 seri port üzerinden ayrıca lokal olarak bağlanabilme
Yönetim ÖzellikleriLCD panel üzerinden bilgilendirme
Yönetim ÖzellikleriEthernet üzerinden GUI, Telnet, ve SSH Sistem monitörü
Yönetim ÖzellikleriE-mail, LAN broadcast, fax, SNMP traps, SMS, ve MSN teknikleriyle sistem bilgilendirme özellikleri
Yönetim ÖzellikleriLED bilgilendirme
Yönetim ÖzellikleriSistem kompenentlerinin kontrolü, ısı kontrolleri
Ürün İçeriği
RAID
Multiple arrays configurable with dedicated or global hot spares
RAID levels supported: RAID 0, 1 (0+1), 3, 5, 10, 30, 50, and NRAID
Online expansion by:
Adding new drives
Copying and replacing drives with drives of larger capacity
Automatic background rebuilds
Configurable stripe size and write policy per array
Intelligent drive handling:
In degraded mode: skips irreparable blocks to continue rebuild
In normal operation: data-block verification and repair
Host Interface
Two (2) SCSI-320 channels through four (4) VHDCI 68-pin SCSI ports; SCSI-160 backward compatible
Concurrent I/O commands
Tagged command queuing up to 256
Variable stripe sizes per logical drive
Optimization setting for random or sequential I/Os
Drive Interface
Eight (8) 3Gbps SATA-II (3Gbps) , hot-swappable drive trays that accommodate 1-inch pitch, 3.5-inch SATA-I or SATA-II (3Gbps) disk drives
Automatic bad-sector reassignment
Dedicated bandwidth to each connected drive
System Components
Single controller configuration provides full RAID functionalities
One (1) tower/desktop convertible enclosure
One (1) RAID controller module
One (1) 128MB SDRAM DIMM module (pre-installed module)
Two (2) 250W power supply units
Two (2), hot-swappable, redundant, single-fan cooling modules running in high/low speeds
Eight (8) hot-swappable drive trays
Optional battery backup unit (BBU)
Management
Front LCD control panel for setup and configuration
10/100 BaseT Ethernet for out-of-band management
One (1) RS-232C serial port for local access to firmware-embedded utility
VT-100 terminal emulation via RS-232C
Telnet access via onboard Ethernet port
Java-based RAIDWatch® GUI manager:
Cross-platform, remote administration with SSL
Out-of-band access via Ethernet
Centralized management to monitor and administer multiple RAID units on one screen
Configuration Client for real-time event notification over Email, Fax, LAN broadcast, SNMP Traps, MSN messenger, ICQ, SMS short messages, and the configuration utility screen
SNMP agent support:
SNMP trap event notification with plain-text event message (no MIB file required)
SNMP V2.0 MIB file support with get-and-set commands
Indicators
Onboard alarm is triggered when one of the following modules fails:
Cooling module
Power supply unit
Hard drive
Violated temperature thresholds
Module status LED indicators:
Two (2) per drive tray
One (1) per cooling module
One (1) per power supply unit
One (1) per BBU module
Three (3) per LCD panel
Four (4) per RAID controller module
Two (2) per Ethernet port
Module failure alert through I2C bus
Intelligent Drive Handling
If two bad blocks occur on two member drives of an array, the integrity of the stored data is endangered. Media Scan, Infortrend's innovative intelligent drive handling function, retrieves data from the damaged sectors. Media Scan handles low quality drives in both the degraded mode and during the rebuild process. For additional data security, other intelligent drive management features include the transparent resetting of hung hard drives, power-failure management, and bad-drive handling during LD expansion.
Task Scheduler
The Task Scheduler is combined with Media Scan so that the scanning operation can be scheduled beginning at a specified start time and repeating at the configurable intervals. The operation is thus hands free. Each such schedule can be defined to operate on individual hard drives, all drives of a certain class, all member drives of a specified logical drive, or all member drives of all logical drives.
Interfaces
Four VHDCI (4) ports in two (2) dual-stacked VHDCI SCSI connectors
One (1) COM port (38400, n, 8, 1)
One (1) 10/100BaseT Ethernet port
Power Supply Module
Two (2) power supplies with PFC
Input: 90VAC at 8A, 260VAC at 4A with PFC (auto-switching)
47 ~ 63Hz
Output: (Maximum output: 250 Watts)
+12.0V 16A max.
+ 5.0V 20A max.
+ 3.3V 20A max.
Cooling Module
Two (2) redundant single-fan cooling modules
Maximum air flow (each module): High speed: 53 CFM Low speed: 23 CFM
Environmental Specifications
Operating temperature: 0 to 40°C
Non-operating temperature: - 40º to 60ºC
Relative humidity: 5~95%, non-condensing
Operating altitude: 0 to 10,000 ft 0 to 40,000 ft
Dimensions
Chassis: 362.3(H) x 128(W) x 327.6(L) mm - default tower
Package: 450H x 500W x 600D mm
System Weight
Net weight: 22.5kg
Gross weight: 21kg
EonStor 8-Bay Cube SAS-SATA
Piyalepaşa Bulvarı, Memorial Center A Blok K:10, 34384 Okmeydanı/İSTANBUL Tel: 212.320 88 20 | ANKARA Şb: 312.466 70 43
©2006 Computorium - Tüm hakları saklıdır - Computorium tescilli marka ismidir - Computorium AŞ, bir CAVME Group kuruluşudur.
Computorium A.Ş. bir CAVME Group kuruluşudur.
Design By Komote Webber