| EonStor 8-Bay Cube SAS-SATA |
| Uncompressed 10-bit 1080 HD Kurgu EonStar A08S-C2131 8 slotlu SATA II-SAS Raid Subsystem |
SAS host interface technology High bandwidth, provide satisfactory processing efficiency even in transaction-intensive and throughput-demanding applications
5th generation, ASIC400 architecture:
* Hardware RAID5 + RAID6 engine
Advanced fault tolerance, ensure data integrity even in multiple drive failure events Supports video streams up to uncompressed 10-bit 1080 HD Can be used to do video and content editing projects Powerful management suite, SANWatch, support Easy management and monitoring of your subsystem anywhere through Intranet or Internet Convertible configuration: tower or desktop Flexibly fit the space allocations; when in desktop configuration, four subsystems can be stacked together Two colors of enclosure: black or silver Consistent integration with the color tone of the setting environment
Flexible choice:
* 1 PSU and 1 SAS port (A08S-C2131) * 2 PSUs and 2 SAS ports (A08S-C2132) * optional installation of 1 additional PSU for A08S-C2131
Make your money spent on what you really need Drive interface: 3Gbps SATA-II disk drives Affordable choice for high capacity Fault-tolerant hardware Redundant PSU and cooling modules enable high availability
Low noise:
* noise lower than 41 dBA when the fans in low speed mode
Low acoustic noise for SOHO or small-business environments
Host Interface
* One (1) SAS wide port (SFF-8088) with 12Gbps bandwidth * Concurrent I/O commands * Default tagged command queuing: 256
Drive Interface
* Eight (8) 3.0Gbps SATA-II, hot-swappable drive trays * Accommodates 1-inch pitch, 3.5-inch SATA-II (3Gbps) disk drives * S.M.A.R.T. and NCQ support * Automatic bad-sector reassignment * Dedicated bandwidth to each connected drive * Drive buffer on/off switch
Controller Single Form Factor 8-bay Cube tower or desktop convertible RAID functionality
* Global or Dedicated hot-spare * RAID levels supported: RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60 * Online expansion by: o Adding new drives o Copying and replacing drives with drives of larger capacity * RAID migration * Configurable stripe size and write policy per array * Intelligent drive handling: o In degraded mode: skips irreparable blocks to continue rebuild o In normal operation: data-block verification and repair
System Components
* One (1) tower/desktop convertible enclosure (black or silver) * One(1) RAID controller module * One (1) 256 MB DIMM module (pre-installed module) * One (1) 250W power supply unit * Two (2) redundant, dual-speed cooling modules * Eight (8), hot-swappable drive trays (black or silver) * Optional Li-Ion battery backup unit (BBU), life expectancy and charge level aware
Management
* Java-based SANWatch software * COM1 serial port for local access to firmware-embedded utility * Automated cache flush and caching mode operation per enclosure status * GUI, Telnet, and SSH system monitoring via Ethernet * Firmware-embedded manager via RS-232C (audio jack) that is platform independent * Various event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN * LCD keypad panel for monitoring and access to all configuration options * Module status LED indicators: * Component presence detection & thermal sensors via I2C bus
Dimensions 370(H) x 155(W) x 343(D) mm Weight 11.4 kg |
|
HD Video Kurgu Grafik işleme Video işleme Sayfa tasarımı CAD-CAM |
| Masaüstünde yüksek kapasiteli depolama imkanı. 8 TB'ye kadar büyüyebilen kapasite. Yüksek performans ve yüksek güvenlik seviyesi. Masaüstü yayıncılık, sayfa tasarımı, grafik uygulamaları, video uygulamaları için çok uygun. |
| Arabirimler1 Adet SAS wide port (SFF-8088) 12Gbps bandwidth |
| ArabirimlerSATA II 3GBps Diskler |
| Raid SeviyeleriRAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60 |
| Güç Kaynağı / FAN1 Adet Power Supply Ünitesi(250W), Dual Speed Redundant Fan Modül |
| GüvenlikSNMP Desteği |
| Disk YönetimiS.M.A.R.T. ve NCQ desteği |
| Disk YönetimiOtomatik bad-sector denetleyici |
| Disk YönetimiBağlantılı herbir disk için tanımlanabilir bant genişliği |
| Disk YönetimiDrive buffer on/off switch |
| KontrollörTek |
| Ünite YapısıDik veya yatık şekilde kullanım imkanı |
| Raid ÖzellikleriOnline olarak yeni disk ekleme, kopyalama ve düzeltme işlemleri |
| Raid ÖzellikleriRAID migration |
| Raid ÖzellikleriConfigurable stripe size and write policy per array |
| Ünite Bellek256 MB DDR Ram |
| Yönetim ÖzellikleriWeb arayüzü üzerinden JAVA tabanlı SAN-Watch yazılımı |
| Yönetim ÖzellikleriCOM1 seri port üzerinden ayrıca lokal olarak bağlanabilme |
| Yönetim ÖzellikleriLCD panel üzerinden bilgilendirme |
| Yönetim ÖzellikleriEthernet üzerinden GUI, Telnet, ve SSH Sistem monitörü |
| Yönetim ÖzellikleriE-mail, LAN broadcast, fax, SNMP traps, SMS, ve MSN teknikleriyle sistem bilgilendirme özellikleri |
| Yönetim ÖzellikleriLED bilgilendirme |
| Yönetim ÖzellikleriSistem kompenentlerinin kontrolü, ısı kontrolleri |
RAID Multiple arrays configurable with dedicated or global hot spares RAID levels supported: RAID 0, 1 (0+1), 3, 5, 10, 30, 50, and NRAID Online expansion by: Adding new drives Copying and replacing drives with drives of larger capacity Automatic background rebuilds Configurable stripe size and write policy per array Intelligent drive handling: In degraded mode: skips irreparable blocks to continue rebuild In normal operation: data-block verification and repair Host Interface Two (2) SCSI-320 channels through four (4) VHDCI 68-pin SCSI ports; SCSI-160 backward compatible Concurrent I/O commands Tagged command queuing up to 256 Variable stripe sizes per logical drive Optimization setting for random or sequential I/Os Drive Interface Eight (8) 3Gbps SATA-II (3Gbps) , hot-swappable drive trays that accommodate 1-inch pitch, 3.5-inch SATA-I or SATA-II (3Gbps) disk drives Automatic bad-sector reassignment Dedicated bandwidth to each connected drive System Components Single controller configuration provides full RAID functionalities One (1) tower/desktop convertible enclosure One (1) RAID controller module One (1) 128MB SDRAM DIMM module (pre-installed module) Two (2) 250W power supply units Two (2), hot-swappable, redundant, single-fan cooling modules running in high/low speeds Eight (8) hot-swappable drive trays Optional battery backup unit (BBU) Management Front LCD control panel for setup and configuration 10/100 BaseT Ethernet for out-of-band management One (1) RS-232C serial port for local access to firmware-embedded utility VT-100 terminal emulation via RS-232C Telnet access via onboard Ethernet port Java-based RAIDWatch® GUI manager: Cross-platform, remote administration with SSL Out-of-band access via Ethernet Centralized management to monitor and administer multiple RAID units on one screen Configuration Client for real-time event notification over Email, Fax, LAN broadcast, SNMP Traps, MSN messenger, ICQ, SMS short messages, and the configuration utility screen SNMP agent support: SNMP trap event notification with plain-text event message (no MIB file required) SNMP V2.0 MIB file support with get-and-set commands Indicators Onboard alarm is triggered when one of the following modules fails: Cooling module Power supply unit Hard drive Violated temperature thresholds Module status LED indicators: Two (2) per drive tray One (1) per cooling module One (1) per power supply unit One (1) per BBU module Three (3) per LCD panel Four (4) per RAID controller module Two (2) per Ethernet port Module failure alert through I2C bus Intelligent Drive Handling If two bad blocks occur on two member drives of an array, the integrity of the stored data is endangered. Media Scan, Infortrend's innovative intelligent drive handling function, retrieves data from the damaged sectors. Media Scan handles low quality drives in both the degraded mode and during the rebuild process. For additional data security, other intelligent drive management features include the transparent resetting of hung hard drives, power-failure management, and bad-drive handling during LD expansion. Task Scheduler The Task Scheduler is combined with Media Scan so that the scanning operation can be scheduled beginning at a specified start time and repeating at the configurable intervals. The operation is thus hands free. Each such schedule can be defined to operate on individual hard drives, all drives of a certain class, all member drives of a specified logical drive, or all member drives of all logical drives. Interfaces Four VHDCI (4) ports in two (2) dual-stacked VHDCI SCSI connectors One (1) COM port (38400, n, 8, 1) One (1) 10/100BaseT Ethernet port Power Supply Module Two (2) power supplies with PFC Input: 90VAC at 8A, 260VAC at 4A with PFC (auto-switching) 47 ~ 63Hz Output: (Maximum output: 250 Watts) +12.0V 16A max. + 5.0V 20A max. + 3.3V 20A max. Cooling Module Two (2) redundant single-fan cooling modules Maximum air flow (each module): High speed: 53 CFM Low speed: 23 CFM Environmental Specifications Operating temperature: 0 to 40°C Non-operating temperature: - 40º to 60ºC Relative humidity: 5~95%, non-condensing Operating altitude: 0 to 10,000 ft 0 to 40,000 ft Dimensions Chassis: 362.3(H) x 128(W) x 327.6(L) mm - default tower Package: 450H x 500W x 600D mm System Weight Net weight: 22.5kg Gross weight: 21kg
|
|