| EonStar A08U-C2411 8 slotlu SATA II-SCSI Raid Subsystem |
RAID Multiple arrays configurable with dedicated or global hot spares RAID levels supported: RAID 0, 1 (0+1), 3, 5, 10, 30, 50, and NRAID Online expansion by: Adding new drives,copying and replacing drives with drives of larger cap. Automatic background rebuilds, Configurable stripe size and write policy per array Intelligent drive handling: In degraded mode: skips irreparable blocks to continue rebuild In normal operation: data-block verification and repair
INTERFACE One (1) SCSI-320 channel through two (2) VHDCI 68-pin SCSI ports; SCSI-160 backward compatible Concurrent I/O commands ,Tagged command queuing up to 256 Variable stripe size per logical drive ,Optimization setting for random or sequential I/Os
DISK INTERFACE Eight (8) 3Gbps SATA-II (3Gbps) , hot-swappable drive trays that accommodate 1-inch pitch, 3.5-inch SATA-I or SATA-II (3Gbps) disk drives Automatic bad-sector reassignment,Dedicated bandwidth to each connected drive
SYSTEM COMPONENTS One (1) tower/desktop convertible enclosure One (1) RAID controller module One (1) 128MB SDRAM DIMM module (pre-installed on the controller module) One (1) 250W power supply unit Two (2), hot-swappable, redundant, single-fan cooling modules running in high/low speeds Management
Front LCD control panel for setup and configuration 10/100 BaseT Ethernet for out-of-band management One (1) RS-232C serial port for local access to firmware-embedded utility VT-100 terminal emulation via RS-232C Telnet access via onboard Ethernet port Java-based RAIDWatch® GUI manager: Cross-platform, remote administration with SSL Out-of-band access via Ethernet Centralized management to monitor and administer multiple RAID units on one screen Configuration Client for real-time event notification over Email, Fax, LAN broadcast, SNMP Traps, MSN messenger, ICQ, SMS short messages, and the configuration utility screen
SNMP SUPPORT SNMP trap event notification with plain-text event message (no MIB file required) SNMP V2.0 MIB file support with get-and-set commands
INDICATORS Onboard alarm is triggered when one of the following modules fails: RAID controller module Cooling module Power supply unit Hard drive Violated temperature thresholds
INTELLIGENT DRIVE HANDLING If two bad blocks occur on two member drives of an array, the integrity of the stored data is endangered. Media Scan, Infortrend's innovative intelligent drive handling function, retrieves data from the damaged sectors. Media Scan handles low quality drives in both the degraded mode and during the rebuild process. For additional data security, other intelligent drive management features include the transparent resetting of hung hard drives, power-failure management, and bad-drive handling during LD expansion.
TASK SCHEDULER The Task Scheduler is combined with Media Scan so that the scanning operation can be scheduled beginning at a specified start time and repeating at the configurable intervals. The operation is thus hands free. Each such schedule can be defined to operate on individual hard drives, all drives of a certain class, all member drives of a specified logical drive, or all member drives of all logical drives. |
|
Grafik işleme Video işleme Sayfa tasarımı CAD-CAM |
| Masaüstünde yüksek kapasiteli depolama imkanı. 8 TB'ye kadar büyüyebilen kapasite. Yüksek performans ve yüksek güvenlik seviyesi. Masaüstü yayıncılık, sayfa tasarımı, grafik uygulamaları, video uygulamaları için çok uygun. |
| ArabirimlerSCSI 320 |
| ArabirimlerSATA II 3GBps Diskler |
| Raid Seviyeleri0, 1 (0+1), 3, 5, 10, 30, 50 |
| Güç Kaynağı / FANRedundant Hot-Swap |
| GüvenlikSNMP Desteği |
RAID Multiple arrays configurable with dedicated or global hot spares RAID levels supported: RAID 0, 1 (0+1), 3, 5, 10, 30, 50, and NRAID Online expansion by: Adding new drives Copying and replacing drives with drives of larger capacity Automatic background rebuilds Configurable stripe size and write policy per array Intelligent drive handling: In degraded mode: skips irreparable blocks to continue rebuild In normal operation: data-block verification and repair Host Interface Two (2) SCSI-320 channels through four (4) VHDCI 68-pin SCSI ports; SCSI-160 backward compatible Concurrent I/O commands Tagged command queuing up to 256 Variable stripe sizes per logical drive Optimization setting for random or sequential I/Os Drive Interface Eight (8) 3Gbps SATA-II (3Gbps) , hot-swappable drive trays that accommodate 1-inch pitch, 3.5-inch SATA-I or SATA-II (3Gbps) disk drives Automatic bad-sector reassignment Dedicated bandwidth to each connected drive System Components Single controller configuration provides full RAID functionalities One (1) tower/desktop convertible enclosure One (1) RAID controller module One (1) 128MB SDRAM DIMM module (pre-installed module) Two (2) 250W power supply units Two (2), hot-swappable, redundant, single-fan cooling modules running in high/low speeds Eight (8) hot-swappable drive trays Optional battery backup unit (BBU) Management Front LCD control panel for setup and configuration 10/100 BaseT Ethernet for out-of-band management One (1) RS-232C serial port for local access to firmware-embedded utility VT-100 terminal emulation via RS-232C Telnet access via onboard Ethernet port Java-based RAIDWatch® GUI manager: Cross-platform, remote administration with SSL Out-of-band access via Ethernet Centralized management to monitor and administer multiple RAID units on one screen Configuration Client for real-time event notification over Email, Fax, LAN broadcast, SNMP Traps, MSN messenger, ICQ, SMS short messages, and the configuration utility screen SNMP agent support: SNMP trap event notification with plain-text event message (no MIB file required) SNMP V2.0 MIB file support with get-and-set commands Indicators Onboard alarm is triggered when one of the following modules fails: Cooling module Power supply unit Hard drive Violated temperature thresholds Module status LED indicators: Two (2) per drive tray One (1) per cooling module One (1) per power supply unit One (1) per BBU module Three (3) per LCD panel Four (4) per RAID controller module Two (2) per Ethernet port Module failure alert through I2C bus Intelligent Drive Handling If two bad blocks occur on two member drives of an array, the integrity of the stored data is endangered. Media Scan, Infortrend's innovative intelligent drive handling function, retrieves data from the damaged sectors. Media Scan handles low quality drives in both the degraded mode and during the rebuild process. For additional data security, other intelligent drive management features include the transparent resetting of hung hard drives, power-failure management, and bad-drive handling during LD expansion. Task Scheduler The Task Scheduler is combined with Media Scan so that the scanning operation can be scheduled beginning at a specified start time and repeating at the configurable intervals. The operation is thus hands free. Each such schedule can be defined to operate on individual hard drives, all drives of a certain class, all member drives of a specified logical drive, or all member drives of all logical drives. Interfaces Four VHDCI (4) ports in two (2) dual-stacked VHDCI SCSI connectors One (1) COM port (38400, n, 8, 1) One (1) 10/100BaseT Ethernet port Power Supply Module Two (2) power supplies with PFC Input: 90VAC at 8A, 260VAC at 4A with PFC (auto-switching) 47 ~ 63Hz Output: (Maximum output: 250 Watts) +12.0V 16A max. + 5.0V 20A max. + 3.3V 20A max. Cooling Module Two (2) redundant single-fan cooling modules Maximum air flow (each module): High speed: 53 CFM Low speed: 23 CFM Environmental Specifications Operating temperature: 0 to 40°C Non-operating temperature: - 40º to 60ºC Relative humidity: 5~95%, non-condensing Operating altitude: 0 to 10,000 ft 0 to 40,000 ft Dimensions Chassis: 362.3(H) x 128(W) x 327.6(L) mm - default tower Package: 450H x 500W x 600D mm System Weight Net weight: 22.5kg Gross weight: 21kg
|
| |